ANALYTICAL INSTRUMENTS / CONDUCTIVITY SENSOR
MULTI-RANGING CONDUCTIVITY - ATN 3411

ATN 3411 measures Conductivity, TDS, NaCl and temperature. In extended conductivity and TDS ranges (up to 500 mS/cm and 400 g/L respectively) the instrument automatically chooses the best scale. This instrument utilizes a 4-ring potentiometric probe with platinum sensors that offers greater versatility over typical amperometric designs. By utilizing the 4-ring method, it is possible to measure very low or high conductivity levels without changing probes.
Calibration is automatic at 1 point with 6 memorized buffers. The meter has 3 options for temperature compensation: ATC between 0 to 60.0°C, MTC and NoTC. Other features include a read lock function, stability indicator, GLP and PC compatibility via optional ATN 03111 software.

 

  • Features

  • Auto-ranging
  • 4-ring potentiometric conductivity probe with internal temperature sensor
  • Automatic (ATC), Manual (MTC) or No Temperature Compensation (NoTC)
  • Good Laboratory Practice
  • PC compatible

  • Specifications :
  • Range: (Conductivity) 0.00 to 29.99 μS/cm; 30.0 to 299.9 μS/cm; 300 to 2999 μS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual Conductivity)
  • Range: (TDS) 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (actual TDS), with 0.80 conversion factor
  • Range: (NaCl) 0.0 to 400.0%
  • Range: (Temp) -9.9 to 120.0°C
  • Resolution: (Conductivity) 0.01 μS/cm; 0.1 μS/cm; 1 μS/cm; 0.01 mS/cm; 0.1 mS/cm
  • Resolution: (TDS) 0.01 mg/L; 0.1 mg/L; 1 mg/L; 0.01 g/L; 0.1 g/L
  • Resolution: (NaCl) 0.1%
  • Resolution: (Temp) 0.1°C
  • Accuracy: (Conductivity) ±1% of reading ± (0.05 μS/cm or 1 digit)
  • Accuracy: (TDS) ±1% of reading ± (0.03 mg/L or 1 digit)
  • Accuracy: (NaCl) ±1% of reading
  • Accuracy: (Temp) ±0.4°C
  • Calibration: (Conductivity) automatic, 1 point with 6 memorized values (84, 1413,5000, 12880, 80000, 111800 μS/cm)
  • Calibration: (NaCl) 1 point, with MS 8148 calibration solution
  • Calibration: (Temp) 2-point, at 0 and 50°C (32 and 122°F)
  • Temperature Compensation: automatic or manual, 0 to 60°C (32 and 140°F)
  • Temperature Coefficient: selectable from 0.00 to 6.00%/°C (Conductivity and TDS only)
  • TDS Conversion Factor: selectable from 0.40 to 0.80 (default value: 0.50)
  • Probe: (included) MS 87421, 4-ring platinum, internal temperature sensor
  • Auto-off: after 5 minutes of non-use (can be disabled)
  • Power Supply: (included) 12 Vdc adapter
  • Environment: 0 to 50°C (32 to 122°F); RH max 95%
  • Dimensions/Weight: 240 x 182 x 74 mm / 1.1 kg