FLOW METER / ULTRASONIC FLOW METER
ULTRASONIC FLOW METER-ATNSIONIC 200

ATNSIONIC-200 is a micro-controller based full bore type Ultrasonic Flow Meter, specially used for various industrial applications. These flow meters accurately measures the flow rate of liquid in closed pipes. Due to its simple& rigid design, the flow meter is an obstruction-less and maintenance free instrument in place of conventional mechanical Flow measuring devices. The system is well suited to most environments. Programming of the flow meter is simple and can be accomplished with 4 keys available on instrument, It provides access to an extensive range of diagnostic information. ELECTRONET manufactures several flow meter consoles to meet the specific requirements of various applications.

TECHNICAL SPECIFICATIONS

 

Media

: Sonically conductive liquids

 

 

 

Viscosity

: 200 cp maximum

 

 

 

Line Size

: 50 NB to 2000 NB

 

 

 

Display

: LCD Display - 6 digit for Flow Rate & 8 digit for Totalised Flow

Calibration Range

: As per requirement (Factory Calibrated)

 

 

Acoustic Paths

: Single, Dual & four path

 

 

 

Accuracy*

:

Line Size

±0.5% of MV

±1% of MV

±2% of MV

 

 

 

50 to 300NB

Single path

----

----

 

 

 

350 to 600NB

Dual path

Single path

----

 

Turbidity

 

650 to 2000NB

Four path

Dual path

Single path

 

: Smaller than 10,000ppm (mg/ltr) with a low level of air bubble content

Linearity

: ± 0.5% of M.V.

 

 

 

 

Repeatability

: ± 0.2% of M.V.

 

 

 

 

Temperature Coefficient

: ± 0.05% perOC

 

 

 

 

Process Temperature

: -20OC to 85OC maximum

 

 

 

Process Pressure

: 15 kg/cm2maximum

 

 

 

Material of Construction

: Flow tube - SS / MS / CS

 

 

 

Power Supply

: 1) 230V AC,50 Hz

 

 

 

 

 

2) 24V DC,+20%, -15% / 20 Watts Max.

 

 

Communication Port

: RS-485 MODBUS RTU

 

 

 

Analog Output

: 4 - 20 mA

 

 

 

 

Response Time

: < 1Sec

 

 

 

 

Transmitter Enclosure

: Die Cast Aluminum IP-66, flow tube IP-68

 

 

Process Connections

: ANSI 150 flanged, as per table B 16.5

 

 

Operating Conditions

: Temperature -20 to 75OC / Humidity 5 to 95% non condensing

Data logging

: for 10 years (per day 1 sample) - Optional

 

 

Sensor Pair

: As per requitement

 

 

 

Sensor MOC

: SS 316

 

 

 

 

Electronics

: 1) Integral

 

 

 

 

 

 

2) Remote

 

 

 

 

Specifications