FLOW METER / ULTRASONIC FLOW METER
CLAMP ON TYPE ULTRASONIC FLOW METER- ATNSIONIC-200C

ATNSIONIC 200C Clamp-on Ultrasonic flow meters measure liquids in industrial applications. Because the sensor is clamped on to the outside of the pipe, it is immune to the process compatibility concerns of an in-line flow metering technology.

ATNSIONIC 200C clamp-on ultrasonic flow meter operates using transit time measurement. By measuring the time it takes a sonic signal to travel a known distance with the flow stream and another signal travelling against the flow stream, it determines the velocity of the fluid being measured. With the sonic properties of the fluid and the pipe material factored in, users get an extremely repeatable accuracy on the volumetric flow rate being measured. Because the transmitter can process the signal of one or two sensors, it ensures additional economy and the ability to compare or contrast two flow streams, if required. The product is ideal for users looking for a process measurement device that is easy to install and can maintain flow measurement for clean liquids.

 

ATNSIONIC 200C clamp-on ultrasonic flow meters can be installed without stopping the process or having cut into the pipe line. It is ideal for process measurement in applications where users previously had not installed an in-line flow meter and for applications where large line sizes or exotic materials are required for in-line measurement technologies.

TECHNICAL SPECIFICATIONS

Media

: Sonically conductive liquids

 

 

Viscosity

: 200 cp maximum

 

 

 

 

Turbidity

: Smaller than 10,000ppm (mg/ltr) with a low level of air bubble content

Flow Range

: -12 m/s to +12 m/s (40 ft/s)

 

 

Power Supply

: 1) AC Version: 85-260 V AC, 50/60 Hz

Accuracy*

:

2) DC Version: 24 V DC, +20% , -15%

Line Size

 

±1% of MV

 

±2% of MV

 

 

 

50 to 300NB

 

Single path

 

----

 

 

 

350 to 600NB

 

Dual path

 

Single path

 

Acoustic Paths

:

650 to 2000NB

 

Dual path

 

Single path

 

Single, Dual path

 

 

 

 

Display

: LCD Display

 

 

 

 

Communication Interface

: RS 232 OR RS 485 MODBUS RTU

Data Logger

: Internal data logging

 

 

Operating Temperature - Transmitter

: -40°C to 60°C

 

 

 

 

Operating Temperature - Transducer

: -40°C to 80°C (Standard), -40°C tp 150°C (Option)

Enclosure

: Wall mounted / Handheld, IP 65 Material.

Pipe Size

: 25 mm (1”) to 2000 mm (80)”, wall thickness <20mm

Pipe material compatibility

: MS / SS / Cast Iron / Plastic

 

 

Analog Output

: Isolated 4 to 20 mA ,650 Ohm load

 

 

Humidity

: Up to 99% relative humidity (non condensing)

Transmitter

: Cast-Aluminium / ABS Plastic, IP-65 (NEMA 4x)

Sensor

: Encapsulated design standard cable length : 9 mtr., optional upto 15 mtr.

Sensor Mounting

: 1) ‘V’ method

 

 

 

 

 

 

2) ‘Z’ method

 

 

 

 

Ambient Conditions

: Operating temperature: -10 °C to +60 °C (14 °F to 140 °F)

Sensor Type

: S(DN50-DN200), M(DN250-DN800), L(DN850-DN2000)