- Home
- ยป
- Our Products
- »
- WATER TREATMENT
WATER TREATMENT
Wholesale Distributor of a wide range of products which include pump starter panel 33m, single phase chiller controllers, water atm: smart card, submersible pump starter panel - psp 1p 2m, three phase chiller / heat pump controllers and iro controller star delta.
Pump Starter Panel 33M
Product Price: Rs 4,000 / PieceGet Best Price
Product Brochure
Product Details:
Control Method | Automatic |
Nominal Input Current | 15 A |
Auxillary Input Supply | 415VAC +/- 10%, 50Hz, 3-Phase, 4- wire. Display: Current, Fault Messages. |
Display Accuracy | Current : 0.25% rdg +- 1 digits. |
Resolution | Current: 0.1 A |
Environmental | 1] Working Temp 0 to 55 C 2] Storage Temp 10 to 70 C 3] Relative humidity 0 - 95% non-condensing 4] Warm up time 10 Sec |
Enclosure | 1] Mounting Wall mounting. 2] Enclosure 190 (W) X 130 (L) X 70 (H) mm. 3] Terminal Screw ON Terminals. |
Get Best QuoteRequest A Callback
Single Phase Chiller Controllers
Product Price: Rs 4,000 / PieceGet Best Price
Product Brochure
Product Details:
Supply Voltage | 230 VAC +- 15 %. |
Output Contact Rating | 30A,250V for Compressor.7Amps,at 250 VAC for FAN1/FAN2. |
Front Panel | 1) 3 seven Segment bright LED Display. 2) 3 Keys for settings. 3) Fault indication by Red LED. |
Sensing | 1) Temperature, HP, LP for compressor. 2) Current Voltage sensing. |
SPECIFICATION
Get Best QuoteRequest A Callback
Water ATM: Smart Card
Product Price: Rs 13,500 / PieceGet Best Price
Product Brochure
Product Details:
Flow Sensor | Pulse Type |
Water Inlet Connection | 3/4" Solvent Cementable |
Level Sensing | Treated Water Level Floaty |
Supply Voltage | 90-270 VAC / DC. |
Display | 2.8" TFT (Monochrome) |
Programming Keys | 5 |
Water Outlet Connection | 3/4" Solvent Cementable. |
Water Column | 1 m (min) |
Working Temp | 0 to 55 deg C |
Storage Temp | -5 to 70 deg C |
Relative Humidity | 0 - 95 % |
Warm up Time | 10 Sec |
The system comprises of state of the art technology, IP65 panel mounted Water ATM controller, internally mounted Flow Sensor, a 12 VDC (230VAC optional)solenoid valve and suitable piping with convenient external inlet and outlet connections. Water ATM controller has a 2.8 inch LCD display along with 5 nos. of programming keys. This facilitates selection and navigation through the menu driven setting options. The controller also features built in RFID reader/writer, Real Time Clock, Pulse type Flow Sensor interface, control output for Solenoid Valve.
Automation Philosophy:
The Proton Automatic Dispenser, delivers water to an individual by his placing the RFID card (Smart Card) on the Proton ATM Controller on the dispenser panel. Controller opens the solenoid valve to dispense a set batch of water Automatic Dispensing Machine provides for initialising a set of RFID cards and then charging them with an amount to be spent for getting a predefined batches of water. An RFID card can be initialised from the Proton Water ATM controller. A set of RFID cards can be initialised so that they are recognised by a particular set of Proton ATM Controllers only. Thus avoiding inter vendor usage. An individual card then can be charged with an amount in Rupees through the Proton ATM controller. On receiving a batch of water from the Dispenser, an amount set per batch is deducted from the RFID card, as soon as it is presented to the controller. The controller notifies if the water level in the feed tank is low or if the charge left in the card is inadequate. The controller has an auto calibration function, where a unit batch (1 litre) can be calibrated with the help of known capacity containers of 1, 2 ,5 , 10 or 20 litres. Controller stores the data of amount of water dispensed and total charges made, date wise for a period of month.
SPECIFICATION
1. Working Temp : 0 to 55º C
2. Storage Temp : -5 to 70º C
3. Relative humidity : 0 – 95 % Non-Condensing
4. Warm up time : 10 Sec
1. Mounting : Wall mounting.
2. Dimensions : 250 (W) X 300(H) X 150 (D) mm.
All dimensions are in mm.
Get Best QuoteRequest A Callback
Submersible Pump Starter Panel - PSP 1P 2M
Product Price: Rs 4,000 / PieceGet Best Price
Product Brochure
Product Details:
Rated current | 230VAC |
Nominal Input Current | 30 A |
Accuracy | Current 230VAC +/- 10% , 50Hz. Display: Voltage, Currents of both the Motors, Fault Messages. |
Display Accuracy Voltage | 0.25% +- 1 digits. Current : 0.25% rdg +- 1 digits. |
Resolution | Current: 0.1 A |
Voltage | 1 V |
Environmental | 1] Working Temp 0 to 55 C 2] Storage Temp 10 to 70 C 3] Relative humidity 0 - 95% non-condensing 4] Warm up time 10 Sec |
Enclosure | 1] Mounting Panel mounting. Cut out Size 182(H) X 92(W) 2] Enclosure 105 (W) X 200 (L) X 193 (H) mm. 3] Terminal Screw ON Terminals. |
Get Best QuoteRequest A Callback
Three Phase Chiller / Heat Pump Controllers
Product Price: Rs 4,850 / PieceGet Best Price
Product Brochure
Product Details:
Input Supply | 3 Phase 415 V, 50 HZ AC (3 Phase 3 wire) |
Output Contact Rating | 30A,250V for Compressor.7Amps,at 250 VAC for FAN1/FAN2. |
Front Panel | 1) 4 seven Segment bright LED Display. 2) 3 Keys for settings. 3) Fault indication by Red LED. |
Sensing | 1) Temperature, HP, LP and Flow for compressor. 2) Current, Voltage temp sensing. |
2.While compressor is ON,if HP,LP,Flow Fault occurs then Cmpressor will shut down(OFF).
3.IF UV /OV,UL/OL occurs then Both Pump and compressor will shut down(OFF)
4.If unit in Chiller mode then If temp.goes above setpoint compressor will Start & vice versa.
If unit in a Heat Pump mode then If temp.goes below setpoint compressor will start & vice versa.
SPECIFICATION
Additional Information:
- Pay Mode Terms: T/T (Bank Transfer)
Get Best QuoteRequest A Callback
IRO Controller Star Delta
Product Price: Rs 23,000 / PieceGet Best Price
Product Details:
Supply Voltage | 415VAC +- 10% 50Hz.,3 Phase,4 Wire. |
Voltage | 0.25% +- 1 digits. Current : 0.25% rdg +- 1 digits. |
Voltage Resolution Dispaly | 1 V |
Current Resolution Display | 0.1 A |
Working Temp | 0 to 55 deg C |
Storage Temp | 10 to 70 deg C |
Relative Humidity | 0 - 95 % Non-Condensing |
Warm up Time | 10 Sec |
Mounting | Panel Mounting. |
Dimensions | 165 (W) X 60 (L) X 115 (H). Cutout 157 (W) x 109 (H) |
The Industrial RO control panel provides for very convenient mounting and easy field cable terminations. Removable terminals blocks are provided for easy terminations. Different sizes of terminals are selected for process and power connections to avoid wrong connections. The industrial RO control panel is based on state of the art technology processor. It has 6 digital inputs and four outputs. It also has Conductivity and Flow (pulse type) Sensor inputs. It can be set for Manual pre-treatment operation or Automatic pre-treatment operation. On powering the controller it checks for Raw Water Tank (RWT) level and the Treated Water Tank (TWT) level. On receiving signals that the RWT is not empty and TWT is not full, it starts up the Raw water Pump (RWP). A Low Pressure Switch (LPS) check the pressure developed at the suction of HPP. On receiving the signal that pressure is developed (LPS) at the suction of High Pressure Pump (HPP), it opens the Flush (reject) Solenoid valve for a settable time, ensuring slow flush. After this, the HPP is started for a settable time ensuring fast flush. At the end of this time Flush Solenoid valve is closed and RO is started/operational. The controller continuously checks the pressure (LPS) at the HPP suction. Should it fall, a message is displayed with an LED indication on the front panel. After a settable delay if this condition prevails, the RO is shut with a message on the LCD screen. The system can be restarted only with activation of the Start key or Power reset. If during RO in operation; - RWT empty signal is received, both the pumps stop immediately with a message on the LCD, and an LED indication for RWP level. RO can be restarted on activating Start key or Power reset. - TWT full signal is received, a flush sequence is carried out and then both the pumps stop with a message on the LCD screen and an LED indication. Once TWT full signal goes off, Slow and Fast flush sequence is initiated and RO starts. - High Pressure switch (HPS) activation is received, both the pumps stop immediately with a message on the LCD, and an LED indication for HPS. RO can be restarted on activating Start key or Power reset. - Conductivity value exceeds set High level, a message is displayed till the time value is between High and Very High Limits set. If the Conductivity value exceeds the Very High limit set, both the pumps stop immediately with a message on the LCD. RO can be restarted on activating Start key or Power reset. - Any electrical faults at RWP and / or HPP such as Overload, Dry Run, Over Voltage, Under Voltage the RO stops after the set trip values
SPECIFICATION
Current : 0.25% rdg ± 1 digits.
Voltage Resolution (Dispaly) : 1 V
Current Resolution (Display) : 0.1 A
1. Working Temp : 0 to 55º C
2. Storage Temp : 10 to 70º C
3. Relative humidity : 0 – 95 % Non-Condensing
4. Warm up time : 10 Sec
1. Mounting : Panel mounting.
2. Dimensions : 165 (W) X 60 (L) X 115 (H).
Cutout 157 (W) x 109 (H).
All dimensions are in mm.
Get Best QuoteRequest A Callback
IRO With GSM - Model : 11mm
Product Price: Rs 6,500 / PieceGet Best Price
Product Brochure
Product Details:
Mounting | Panel Mounting. |
Input Voltage | 230VAC,50Hz |
Output Current | 10 |
Resolution | Current: - 0.1 A |
Working Temp | 0 to 55 deg C |
Storage Temp | 10 to 70 deg C |
Relative Humidity | 0 - 95 % Non-Condensin |
Warm up Time | 10 Sec |
Dimensions | 165 (W) X 60 (L) X 115 (H). Cutout 157 (W) x 109 (H). |
Cutout Dimensions | Current Calibration (Offset) Can Be Done At Site |
Field CalibrationField Calibration | Current Calibration (Offset) Can Be Done At Site |
The Industrial RO control panel provides for very convenient mounting and easy field cable terminations. Removable terminals blocks are provided for easy terminations. Different sizes of terminals are selected for process and power connections to avoid wrong connections. The industrial RO control panel is based on state of the art technology processor. It has 6 digital inputs and four outputs. It also has Conductivity and Flow (pulse type) Sensor inputs. It can be set for Manual pre-treatment operation or Automatic pre-treatment operation. On powering the controller it checks for Raw Water Tank (RWT) level and the Treated Water Tank (TWT) level. On receiving signals that the RWT is not empty and TWT is not full, it starts up the Raw water Pump (RWP). A Low Pressure Switch (LPS) check the pressure developed at the suction of HPP. On receiving the signal that pressure is developed (LPS) at the suction of High Pressure Pump (HPP), it opens the Flush (reject) Solenoid valve for a settable time, ensuring slow flush. After this, the HPP is started for a settable time ensuring fast flush. At the end of this time Flush Solenoid valve is closed and RO is started/operational. The controller continuously checks the pressure (LPS) at the HPP suction. Should it fall, a message is displayed with an LED indication on the front panel. After a settable delay if this condition prevails, the RO is shut with a message on the LCD screen. The system can be restarted only with activation of the Start key or Power reset. If during RO in operation; - RWT empty signal is received, both the pumps stop immediately with a message on the LCD, and an LED indication for RWP level. RO can be restarted on activating Start key or Power reset. - TWT full signal is received, a flush sequence is carried out and then both the pumps stop with a message on the LCD screen and an LED indication. Once TWT full signal goes off, Slow and Fast flush sequence is initiated and RO starts. - High Pressure switch (HPS) activation is received, both the pumps stop immediately with a message on the LCD, and an LED indication for HPS. RO can be restarted on activating Start key or Power reset. - Conductivity value exceeds set High level, a message is displayed till the time value is between High and Very High Limits set. If the Conductivity value exceeds the Very High limit set, both the pumps stop immediately with a message on the LCD. RO
SPECIFICATION
1. Working Temp : 0 to 55º C
2. Storage Temp : 10 to 70º C
3. Relative humidity : 0 – 95 % Non-Condensing
4. Warm up time : 10 Sec
1. Mounting : Panel mounting.
2. Dimensions : 165 (W) X 60 (L) X 115 (H).
Cutout 157 (W) x 109 (H).
All dimensions are in mm.
Get Best QuoteRequest A Callback
IRO Controller Panel 11mm
Get Latest Price
Product Details:
Supply Voltage | 415VAC +- 10% 50Hz.,3 Phase,4 Wire. |
Current Range | 0-30 A |
Voltage | 0.25% +- 1 digits |
Current | 0.25% rdg +- 1 digits |
Voltage Resolution Dispaly | 1 V |
Current Resolution Display | 0.1 A |
Working Temp | 0 to 55 deg C |
Storage Temp | 10 to 70 deg C |
Relative Humidity | 0 - 95 % Non-Condensing |
Warm up Time | 10 Sec |
The Industrial RO control panel provides for very convenient mounting and easy field cable terminations. Removable terminals blocks are provided for easy terminations. Different sizes of terminals are selected for process and power connections to avoid wrong connections. The industrial RO control panel is based on state of the art technology processor. It has 6 digital inputs and four outputs. It also has Conductivity and Flow (pulse type) Sensor inputs. It can be set for Manual pre-treatment operation or Automatic pre-treatment operation. On powering the controller it checks for Raw Water Tank (RWT) level and the Treated Water Tank (TWT) level. On receiving signals that the RWT is not empty and TWT is not full, it starts up the Raw water Pump (RWP). A Low Pressure Switch (LPS) check the pressure developed at the suction of HPP. On receiving the signal that pressure is developed (LPS) at the suction of High Pressure Pump (HPP), it opens the Flush (reject) Solenoid valve for a settable time, ensuring slow flush. After this, the HPP is started for a settable time ensuring fast flush. At the end of this time Flush Solenoid valve is closed and RO is started/operational. The controller continuously checks the pressure (LPS) at the HPP suction. Should it fall, a message is displayed with an LED indication on the front panel. After a settable delay if this condition prevails, the RO is shut with a message on the LCD screen. The system can be restarted only with activation of the Start key or Power reset. If during RO in operation; - RWT empty signal is received, both the pumps stop immediately with a message on the LCD, and an LED indication for RWP level. RO can be restarted on activating Start key or Power reset. - TWT full signal is received, a flush sequence is carried out and then both the pumps stop with a message on the LCD screen and an LED indication. Once TWT full signal goes off, Slow and Fast flush sequence is initiated and RO starts. - High Pressure switch (HPS) activation is received, both the pumps stop immediately with a message on the LCD, and an LED indication for HPS. RO can be restarted on activating Start key or Power reset. - Conductivity value exceeds set High level, a message is displayed till the time value is between High and Very High Limits set. If the Conductivity value exceeds the Very High limit set, both the pumps stop immediately with a message on the LCD. RO can be restarted on activating Start key or Power reset. - Any electrical faults at RWP and / or HPP such as Overload, Dry Run, Over Voltage, Under Voltage the RO stops after the set trip value
SPECIFICATION
Current : 0.25% rdg ± 1 digits.
Voltage Resolution (Dispaly) : 1 V
Current Resolution (Display) : 0.1 A
1. Working Temp : 0 to 55º C
2. Storage Temp : 10 to 70º C
3. Relative humidity : 0 – 95 % Non-Condensing
4. Warm up time : 10 Sec
1. Mounting : Panel mounting.
2. Dimensions : 165 (W) X 60 (L) X 115 (H).
Cutout 157 (W) x 109 (H).
All dimensions are in mm.
Get Best QuoteRequest A Callback
IRO Controller Panel 33M
Product Price: Rs 3,800 / PieceGet Best Price
Product Details:
Mounting | Panel Mounting. |
Supply Voltage | 415VAC +- 10% 50Hz. , 3 Phase, 4 Wire. |
Current Range | 0-30 A |
Voltage | 0.25% +- 1 digits. |
Current | 0.25% rdg +- 1 digits. |
Voltage Resolution Dispaly | 1 V |
Current Resolution Display | 0.1 A |
Working Temp | 0 to 55 deg C |
Storage Temp | -5 to 70 deg C |
Relative Humidity | 0 - 95 % Non-Condensing |
Warm up Time | 10 Sec |
Dimensions | 165 (W) X 60 (L) X 115 (H). Cutout 157 (W) x 109 (H). |
The Industrial RO control panel provides for very convenient mounting and easy field cable terminations. Removable terminals blocks are provided for easy terminations. Different sizes of terminals are selected for process and power connections to avoid wrong connections. The industrial RO control panel is based on state of the art technology processor. It has 6 digital inputs and four outputs. It also has Conductivity and Flow (pulse type) Sensor inputs. It can be set for Manual pre-treatment operation or Automatic pre-treatment operation. On powering the controller it checks for Raw Water Tank (RWT) level and the Treated Water Tank (TWT) level. On receiving signals that the RWT is not empty and TWT is not full, it starts up the Raw water Pump (RWP). A Low Pressure Switch (LPS) check the pressure developed at the suction of HPP. On receiving the signal that pressure is developed (LPS) at the suction of High Pressure Pump (HPP), it opens the Flush (reject) Solenoid valve for a settable time, ensuring slow flush. After this, the HPP is started for a settable time ensuring fast flush. At the end of this time Flush Solenoid valve is closed and RO is started/operational. The controller continuously checks the pressure (LPS) at the HPP suction. Should it fall, a message is displayed with an LED indication on the front panel. After a settable delay if this condition prevails, the RO is shut with a message on the LCD screen. The system can be restarted only with activation of the Start key or Power reset. If during RO in operation; - RWT empty signal is received, both the pumps stop immediately with a message on the LCD, and an LED indication for RWP level. RO can be restarted on activating Start key or Power reset. - TWT full signal is received, a flush sequence is carried out and then both the pumps stop with a message on the LCD screen and an LED indication. Once TWT full signal goes off, Slow and Fast flush sequence is initiated and RO starts. - High Pressure switch (HPS) activation is received, both the pumps stop immediately with a message on the LCD, and an LED indication for HPS. RO can be restarted on activating Start key or Power reset. - Conductivity value exceeds set High level, a message is displayed till the time value is between High and Very High Limits set. If the Conductivity value exceeds the Very High limit set, both the pumps stop immediately with a message on the LCD. RO can be restarted on activating Start key or Power reset. - Any electrical faults at RWP and / or HPP
SPECIFICATION
Current : 0.25% rdg ± 1 digits.
Voltage Resolution (Dispaly) : 1 V
Current Resolution (Display) : 0.1 A
1. Working Temp : 0 to 55º C
2. Storage Temp : -5 to 70º C
3. Relative humidity : 0 – 95 % Non-Condensing
4. Warm up time : 10 Sec
1. Mounting : Panel mounting.
2. Dimensions : 165 (W) X 60 (L) X 115 (H).
Cutout 157 (W) x 109 (H).
All dimensions are in mm.
Get Best QuoteRequest A Callback